14 CFR · AIRWORTHINESS STANDARDS: TRANSPORT CATEGORY AIRPLANES

§ 25.1395

Maximum intensities in overlapping beams of forward and rear position lights.

Text as of November 12, 2026

No position light intensity may exceed the applicable values in the following table, except as provided in § 25.1389(b)(3).

Overlaps Maximum intensity
Area A (candles) Area B (candles)
Green in dihedral angle L 10 1
Red in dihedral angle R 10 1
Green in dihedral angle A 5 1
Red in dihedral angle A 5 1
Rear white in dihedral angle L 5 1
Rear white in dihedral angle R 5 1

Where—

(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10 degrees but less than 20 degrees; and

(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20 degrees.

About this text

Source: OFR/GPO eCFR. The wording is reproduced from the dated source, with formatting adapted for reading. The eCFR is an editorial compilation and is not the official legal edition of the CFR.

Check the latest eCFR text →